Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Emerg Microbes Infect ; 11(1): 412-423, 2022 Dec.
Article in English | MEDLINE | ID: covidwho-1585244

ABSTRACT

Although frequently reported since the beginning of the pandemic, questions remain regarding the impact of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) interaction with circulating respiratory viruses in coinfected patients. We here investigated dual infections involving early-pandemic SARS-CoV-2 and the Alpha variant and three of the most prevalent respiratory viruses, rhinovirus (RV) and Influenza A and B viruses (IAV and IBV), in reconstituted respiratory airway epithelial cells cultured at air-liquid interface. We found that SARS-CoV-2 replication was impaired by primary, but not secondary, rhino- and influenza virus infection. In contrast, SARS-CoV-2 had no effect on the replication of these seasonal respiratory viruses. Inhibition of SARS-CoV-2 correlated better with immune response triggered by RV, IAV and IBV than the virus entry. Using neutralizing antibody against type I and III interferons, SARS-CoV-2 blockade in dual infections could be partly prevented. Altogether, these data suggested that SARS-CoV-2 interaction with seasonal respiratory viruses would be modulated by interferon induction and could impact SARS-CoV-2 epidemiology when circulation of other respiratory viruses is restored.


Subject(s)
Coinfection/virology , Influenza A virus/physiology , Influenza B virus/physiology , Respiratory System/virology , Rhinovirus/physiology , SARS-CoV-2/physiology , Virus Replication/physiology , Coinfection/immunology , Humans , Immunity, Innate , Interferons/physiology
2.
J Pediatric Infect Dis Soc ; 10(6): 706-713, 2021 Aug 14.
Article in English | MEDLINE | ID: covidwho-1358465

ABSTRACT

BACKGROUND: Recently, cases of multisystem inflammatory syndrome in children (MIS-C) associated with coronavirus disease 2019 (COVID-19) have been reported worldwide. Negative polymerase chain reaction (RT-PCR) testing associated with positive serology in most of the cases suggests a postinfectious syndrome. Because the pathophysiology of this syndrome is still poorly understood, extensive virological and immunological investigations are needed. METHODS: We report a series of 4 pediatric patients admitted to Geneva University Hospitals with persistent fever and laboratory evidence of inflammation meeting the published definition of MIS-C related to COVID-19, to whom an extensive virological and immunological workup was performed. RESULTS: RT-PCRs on multiple anatomical compartments were negative, whereas anti-severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) immunoglobulin A (IgA) and immunoglobulin G (IgG) were strongly positive by enzyme-linked immunosorbent assay and immunofluorescence. Both pseudoneutralization and full virus neutralization assays showed the presence of neutralizing antibodies in all children, confirming a recent infection with SARS-CoV-2. The analyses of cytokine profiles revealed an elevation in all cytokines, as reported in adults with severe COVID-19. Although differing in clinical presentation, some features of MIS-C show phenotypic overlap with hemophagocytic lymphohistiocytosis (HLH). In contrast to patients with primary HLH, our patients showed normal perforin expression and natural killer (NK) cell degranulation. The levels of soluble interleukin (IL)-2 receptor (sIL-2R) correlated with the severity of disease, reflecting recent T-cell activation. CONCLUSION: Our findings suggest that MIS-C related to COVID-19 is caused by a postinfectious inflammatory syndrome associated with an elevation in all cytokines, and markers of recent T-cell activation (sIL-2R) occurring despite a strong and specific humoral response to SARS-CoV-2. Further functional and genetic analyses are essential to better understand the mechanisms of host-pathogen interactions.


Subject(s)
COVID-19 , Antibodies, Neutralizing , Child , Humans , SARS-CoV-2 , Systemic Inflammatory Response Syndrome
3.
PLoS One ; 16(3): e0248921, 2021.
Article in English | MEDLINE | ID: covidwho-1173655

ABSTRACT

OBJECTIVES: Determine the diagnostic accuracy of two antigen-detecting rapid diagnostic tests (Ag-RDT) for SARS-CoV-2 at the point of care and define individuals' characteristics providing best performance. METHODS: We performed a prospective, single-center, point of care validation of two Ag-RDT in comparison to RT-PCR on nasopharyngeal swabs. RESULTS: Between October 9th and 23rd, 2020, 1064 participants were enrolled. The PanbioTM Covid-19 Ag Rapid Test device (Abbott) was validated in 535 participants, with 106 positive Ag-RDT results out of 124 positive RT-PCR individuals, yielding a sensitivity of 85.5% (95% CI: 78.0-91.2). Specificity was 100.0% (95% CI: 99.1-100) in 411 RT-PCR negative individuals. The Standard Q Ag-RDT (SD Biosensor, Roche) was validated in 529 participants, with 170 positive Ag-RDT results out of 191 positive RT-PCR individuals, yielding a sensitivity of 89.0% (95%CI: 83.7-93.1). One false positive result was obtained in 338 RT-PCR negative individuals, yielding a specificity of 99.7% (95%CI: 98.4-100). For individuals presenting with fever 1-5 days post symptom onset, combined Ag-RDT sensitivity was above 95%. Lower sensitivity of 88.2% was seen on the same day of symptom development (day 0). CONCLUSIONS: We provide an independent validation of two widely available commercial Ag-RDTs, both meeting WHO criteria of ≥80% sensitivity and ≥97% specificity. Although less sensitive than RT-PCR, these assays could be beneficial due to their rapid results, ease of use, and independence from existing laboratory structures. Testing criteria focusing on patients with typical symptoms in their early symptomatic period onset could further increase diagnostic value.


Subject(s)
Antigens, Viral/analysis , COVID-19 Testing , Point-of-Care Systems , Residence Characteristics , SARS-CoV-2/immunology , SARS-CoV-2/isolation & purification , Adult , Female , Humans , Male , SARS-CoV-2/physiology , Sensitivity and Specificity , Time Factors , Viral Load
4.
Microorganisms ; 8(12)2020 Nov 30.
Article in English | MEDLINE | ID: covidwho-1024608

ABSTRACT

Severe acute respiratory syndrome-related coronavirus 2 (SARS-CoV-2) depends on angiotensin converting enzyme 2 (ACE2) for cellular entry, but it might also rely on attachment receptors such as heparan sulfates. Several groups have recently demonstrated an affinity of the SARS-CoV2 spike protein for heparan sulfates and a reduced binding to cells in the presence of heparin or heparinase treatment. Here, we investigated the inhibitory activity of several sulfated and sulfonated molecules, which prevent interaction with heparan sulfates, against vesicular stomatitis virus (VSV)-pseudotyped-SARS-CoV-2 and the authentic SARS-CoV-2. Sulfonated cyclodextrins and nanoparticles that have recently shown broad-spectrum non-toxic virucidal activity against many heparan sulfates binding viruses showed inhibitory activity in the micromolar and nanomolar ranges, respectively. In stark contrast with the mechanisms that these compounds present for these other viruses, the inhibition against SARS-CoV-2 was found to be simply reversible.

5.
mSphere ; 5(6)2020 11 11.
Article in English | MEDLINE | ID: covidwho-920898

ABSTRACT

Viral shedding patterns and their correlations with immune responses are still poorly characterized in mild coronavirus (CoV) disease 2019 (COVID-19). We monitored shedding of viral RNA and infectious virus and characterized the immune response kinetics of the first five patients quarantined in Geneva, Switzerland. High viral loads and infectious virus shedding were observed from the respiratory tract despite mild symptoms, with isolation of infectious virus and prolonged positivity by reverse transcriptase PCR (RT-PCR) until days 7 and 19 after symptom onset, respectively. Robust innate responses characterized by increases in activated CD14+ CD16+ monocytes and cytokine responses were observed as early as 2 days after symptom onset. Cellular and humoral severe acute respiratory syndrome (SARS)-CoV-2-specific adaptive responses were detectable in all patients. Infectious virus shedding was limited to the first week after symptom onset. A strong innate response, characterized by mobilization of activated monocytes during the first days of infection and SARS-CoV-2-specific antibodies, was detectable even in patients with mild disease.IMPORTANCE This work is particularly important because it simultaneously assessed the virology, immunology, and clinical presentation of the same subjects, whereas other studies assess these separately. We describe the detailed viral and immune profiles of the first five patients infected by SARS-CoV-2 and quarantined in Geneva, Switzerland. Viral loads peaked at the very beginning of the disease, and infectious virus was shed only during the early acute phase of disease. No infectious virus could be isolated by culture 7 days after onset of symptoms, while viral RNA was still detectable for a prolonged period. Importantly, we saw that all patients, even those with mild symptoms, mount an innate response sufficient for viral control (characterized by early activated cytokines and monocyte responses) and develop specific immunity as well as cellular and humoral SARS-CoV-2-specific adaptive responses, which already begin to decline a few months after the resolution of symptoms.


Subject(s)
Adaptive Immunity , Betacoronavirus/immunology , Coronavirus Infections/immunology , Coronavirus Infections/virology , Immunity, Innate , Pneumonia, Viral/immunology , Pneumonia, Viral/virology , Viral Load , Virus Shedding , Adult , Aged , Antibodies, Viral/metabolism , Betacoronavirus/isolation & purification , Biomarkers/metabolism , COVID-19 , COVID-19 Testing , Clinical Laboratory Techniques , Coronavirus Infections/diagnosis , Cytokines/metabolism , Humans , Kinetics , Middle Aged , Pandemics , Pneumonia, Viral/diagnosis , SARS-CoV-2 , Severity of Illness Index
6.
Emerg Microbes Infect ; 9(1): 2394-2403, 2020 Dec.
Article in English | MEDLINE | ID: covidwho-845194

ABSTRACT

To understand SARS-CoV-2 immunity after natural infection or vaccination, functional assays such as virus neutralising assays are needed. So far, assays to detect SARS-CoV-2 neutralising antibodies rely on cell-culture based infection assays either using wild type SARS-CoV-2 or pseudotyped viruses. Such assays are labour-intensive, require appropriate biosafety facilities and are difficult to standardize. Recently, a new surrogate virus neutralisation test (sVNT) was described that uses the principle of an ELISA to measure the neutralisation capacity of anti-SARS-CoV-2 antibodies directed against the receptor binding domain. Here, we performed an independent evaluation of the robustness, specificity and sensitivity on an extensive panel of sera from 269 PCR-confirmed COVID-19 cases and 259 unmatched samples collected before 2020 and compared it to cell-based neutralisation assays. We found a high specificity of 99.2 (95%CI: 96.9-99.9) and overall sensitivity of 80.3 (95%CI: 74.9-84.8) for the sVNT. Clinical sensitivity increased between early (<14 days post symptom onset or post diagnosis, dpos/dpd) and late sera (>14 dpos/dpd) from 75.0 (64.7-83.2) to 83.1 (76.5-88.1). Also, higher severity was associated with an increase in clinical sensitivity. Upon comparison with cell-based neutralisation assays we determined an analytical sensitivity of 74.3 (56.4-86.9) and 98.2 (89.4-99.9) for titres ≥10 to <40 and ≥40 to <160, respectively. Only samples with a titre ≥160 were always positive in the sVNT. In conclusion, the sVNT can be used as an additional assay to determine the immune status of COVID-19 infected of vaccinated individuals but its value needs to be assessed for each specific context.


Subject(s)
Betacoronavirus/immunology , Coronavirus Infections/virology , Enzyme-Linked Immunosorbent Assay/methods , Neutralization Tests/methods , Pneumonia, Viral/virology , Adult , Aged , Antibodies, Neutralizing/blood , Antibodies, Viral/blood , Betacoronavirus/genetics , COVID-19 , Coronavirus Infections/blood , Female , Humans , Male , Middle Aged , Pandemics , Pneumonia, Viral/blood , SARS-CoV-2
7.
J Clin Microbiol ; 58(10)2020 09 22.
Article in English | MEDLINE | ID: covidwho-693541

ABSTRACT

The Elecsys Anti-SARS-CoV-2 immunoassay (Roche Diagnostics) was developed to provide accurate, reliable detection of antibodies to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). We evaluated sensitivity, specificity, cross-reactivity, and agreement with a vesicular stomatitis virus-based pseudoneutralization assay for the Elecsys Anti-SARS-CoV-2 immunoassay. Sensitivity and agreement between Elecsys Anti-SARS-CoV-2 immunoassay and pseudoneutralization assay measurements were evaluated using samples from patients with PCR-confirmed SARS-CoV-2 infection, a majority of whom were hospitalized. Specificity was evaluated using samples from routine diagnostic testing/blood donors collected before December 2019 and thus deemed negative for SARS-CoV-2-specific antibodies. Cross-reactivity was evaluated using samples containing a wide range of potentially cross-reacting analytes, purchased from commercial vendors. For sensitivity and specificity, point estimates and 95% confidence intervals (CIs) were calculated. Agreement between the Elecsys Anti-SARS-CoV-2 immunoassay and the pseudoneutralization assay was calculated. The sensitivity of the Elecsys Anti-SARS-CoV-2 immunoassay in patients with prior PCR-confirmed SARS-CoV-2 infection was 99.5% (95% CI, 97.0 to 100.0%) at ≥14 days post-PCR confirmation. Overall specificity (n = 10,453) was 99.80% (95% CI, 99.69 to 99.88%). Only 4/792 samples containing potential cross-reacting analytes were reactive with the Elecsys Anti-SARS-CoV-2 immunoassay, resulting in an overall specificity in this cohort of 99.5% (95% CI, 98.6 to 99.9%). Positive, negative, and overall agreement (n = 46) between the Elecsys Anti-SARS-CoV-2 immunoassay and the pseudoneutralization assay were 86.4% (95% CI, 73.3 to 93.6%), 100% (95% CI, 34.2 to 100%), and 87.0% (95% CI, 74.3 to 93.9%), respectively. The Elecsys Anti-SARS-CoV-2 immunoassay demonstrated high sensitivity (99.5% at ≥14 days post-PCR confirmation) and specificity (99.80%), supporting its use as a tool for identification of past SARS-CoV-2 infection, including use in populations with low disease prevalence.


Subject(s)
Betacoronavirus/isolation & purification , Immunoassay , Antibodies, Viral/blood , Betacoronavirus/immunology , COVID-19 Testing , Clinical Laboratory Techniques , Coronavirus Infections/blood , Coronavirus Infections/diagnosis , Coronavirus Infections/epidemiology , Cross Reactions , Humans , Reproducibility of Results , SARS-CoV-2 , Sensitivity and Specificity
8.
J Clin Med ; 9(8)2020 Jul 24.
Article in English | MEDLINE | ID: covidwho-669678

ABSTRACT

BACKGROUND: Comparative data of SARS-CoV-2 IgM/IgG serology rapid diagnostic tests (RDTs) is scarce. We thus performed a head-to-head comparison of three RDTs. METHODS: In this unmatched case-control study, blood samples from 41 RT-PCR-confirmed COVID-19 cases and 50 negative controls were studied. The diagnostic accuracy of three commercially available COVID-19 RDTs: NTBIO (RDT-A), Orient-Gene (RDT-B), and MEDsan (RDT-C), against both a recombinant spike-expressing immunofluorescence assay (rIFA) and Euroimmun IgG ELISA, was assessed. RDT results concordant with the reference methods, and between whole blood and plasma, were established by the Kendall coefficient. RESULTS: COVID-19 cases' median time from RT-PCR to serology was 22 days (interquartile range (IQR) 13-31 days). Whole-blood IgG detection with RDT-A, -B, and -C showed 0.93, 0.83, and 0.98 concordance with rIFA. Against rIFA, RDT-A sensitivity (SN) was 92% (95% CI: 78-98) and specificity (SP) 100% (95% CI: 91-100), RDT-B showed 87% SN (95% CI: 72-95) and 98% SP (95% CI: 88-100), and RDT-C 100% SN (95% CI: 88-100) and 98% SP (95% CI: 88-100). Against ELISA, SN and SP were above 90% for all three RDTs. CONCLUSIONS: RDT-A and RDT-C displayed IgG detection SN and SP above 90% in whole blood. These RDTs could be considered in the absence of routine diagnostic serology facilities.

9.
Eur J Clin Invest ; 50(10): e13357, 2020 Oct.
Article in English | MEDLINE | ID: covidwho-658264

ABSTRACT

AIMS: To validate the diagnostic accuracy of the Augurix SARS-CoV-2 IgM/IgG rapid immunoassay diagnostic test (RDT) for COVID-19. METHODS: In this unmatched 1:1 case-control study, blood samples from 46 real-time RT-PCR-confirmed SARS-CoV-2 hospitalized cases and 45 healthy donors (negative controls) were studied. Diagnostic accuracy of the IgG RDT was assessed against both an in-house recombinant spike-expressing immunofluorescence assay (rIFA), as an established reference method (primary endpoint), and the Euroimmun SARS-CoV-2 IgG enzyme-linked immunosorbent assays (ELISA) (secondary endpoint). RESULTS: COVID-19 patients were more likely to be male (61% vs 20%; P = .0001) and older (median 66 vs 47 years old; P < .001) than controls. Whole blood IgG-RDT results showed 86% and 93% overall Kendall concordance with rIFA and IgG ELISA, respectively. IgG RDT performances were similar between plasma and whole blood. Overall, RDT sensitivity was 88% (95% confidence interval [95%CI]: 70-96), specificity 98% (95%CI: 90-100), PPV 97% (95%CI: 80-100) and NPV 94% (95%CI: 84-98). The IgG-RDT carried out from 0 to 6 days, 7 to 14 days and > 14 days after the SARS-CoV-2 RT-PCR test displayed 30%, 73% and 100% positivity rates in the COVID-19 group, respectively. When considering samples taken >14 days after RT-PCR diagnosis, NPV was 100% (95%CI:90-100), and PPV was 100% (95%CI:72-100). CONCLUSIONS: The Augurix IgG-RDT done in whole blood displays a high diagnostic accuracy for SARS-CoV-2 IgG in high COVID-19 prevalence settings, where its use could be considered in the absence of routine diagnostic serology facilities.


Subject(s)
Antibodies, Viral/immunology , Betacoronavirus/immunology , Coronavirus Infections/diagnosis , Pneumonia, Viral/diagnosis , Serologic Tests , Spike Glycoprotein, Coronavirus/immunology , Aged , COVID-19 , COVID-19 Testing , COVID-19 Vaccines , Case-Control Studies , Clinical Laboratory Techniques , Female , Fluorescent Antibody Technique , Humans , Immunoglobulin G/immunology , Immunoglobulin M/immunology , Male , Middle Aged , Pandemics , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2 , Sensitivity and Specificity
10.
Emerg Infect Dis ; 26(10): 2494-2497, 2020 10.
Article in English | MEDLINE | ID: covidwho-623762

ABSTRACT

Children do not seem to drive transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). We isolated culture-competent virus in vitro from 12 (52%) of 23 SARS-CoV-2-infected children; the youngest was 7 days old. Our findings show that symptomatic neonates, children, and teenagers shed infectious SARS-CoV-2, suggesting that transmission from them is plausible.


Subject(s)
Betacoronavirus/physiology , Coronavirus Infections/transmission , Nasopharynx/virology , Pneumonia, Viral/transmission , RNA, Viral/analysis , Adolescent , Betacoronavirus/isolation & purification , COVID-19 , Cell Line , Child , Child, Preschool , Coronavirus Infections/diagnosis , Female , Humans , Infant , Infant, Newborn , Male , Pandemics , Pneumonia, Viral/diagnosis , SARS-CoV-2 , Viral Load , Virus Cultivation , Virus Replication
SELECTION OF CITATIONS
SEARCH DETAIL